Customization: | Available |
---|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
PH-803 Digital pH and ORP Controller
Product description:
Beautiful, digital clarity, accurate readings, high resolution, a single instrument can simultaneously solution PH and ORP measurement and control.
The instrument is equipped with universal composite electrode PH and ORP electrodes.
Using wall mount, easy installation, operation and maintenance.
Digital pH-ORP controller with large size LED display for easy reading.
High input impedance avoid measuring error.
Built in SLOPE and CAL. adjust knob, easy for single point
or two points pH calibration.
"PH - ORP" control, the relay "PH" when measuring value
is above the set point for pH.
And the relay "ORP" when measuring value is below the set point for ORP.
Technical Specification:
Model |
PH-803 |
|
|
Measuring range |
PH |
0.00~14.00PH |
|
ORP |
-1999~1999mV |
||
Accuracy |
PH |
±0.1%+0.02PH |
|
ORP |
±5 mV |
||
Resolution |
PH |
0.01PH |
|
ORP |
1mV |
||
Set Range |
PH |
3.50~10.50PH |
|
ORP |
-500~500mV |
||
Environment |
Temperature:0~50ºC Humidity<95℅ |
||
Display |
double 4 LED display reading |
||
Power Supply |
220V±10℅ 50Hz±2℅ |
||
Dimensions |
160mm×102mm×40mm |
||
Weigh |
872g |